Uploaded image for project: 'Derby'
  1. Derby
  2. DERBY-3509

The replication log shipper is not notified when a new replication transmitter is instantiated in MC#handleException.

    XMLWordPrintableJSON

Details

    • Bug
    • Status: Closed
    • Minor
    • Resolution: Fixed
    • 10.4.1.3
    • 10.4.1.3, 10.5.1.1
    • Replication
    • None

    Description

      In MasterController#handleException, a new ReplicationMessageTransmit object is created if the exception is IOException. However, the logShipper is not notified that the new transmitter should be used. A possible solution would be to add a setTransmitter method to AsynchronousLogShipper. Note that the logShipper may contain state information that cannot be discarded, so it cannot be reinstantiated.

      Attachments

        1. Derby3509_1.stat
          0.2 kB
          V.Narayanan
        2. Derby3509_1.diff
          3 kB
          V.Narayanan

        Activity

          People

            narayanan V.Narayanan
            jorgenlo Jorgen Loland
            Votes:
            0 Vote for this issue
            Watchers:
            0 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: