Uploaded image for project: 'Derby'
  1. Derby
  2. DERBY-3509

The replication log shipper is not notified when a new replication transmitter is instantiated in MC#handleException.

    XMLWordPrintableJSON

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: 10.4.1.3
    • Fix Version/s: 10.4.1.3, 10.5.1.1
    • Component/s: Replication
    • Labels:
      None

      Description

      In MasterController#handleException, a new ReplicationMessageTransmit object is created if the exception is IOException. However, the logShipper is not notified that the new transmitter should be used. A possible solution would be to add a setTransmitter method to AsynchronousLogShipper. Note that the logShipper may contain state information that cannot be discarded, so it cannot be reinstantiated.

        Attachments

        1. Derby3509_1.stat
          0.2 kB
          V.Narayanan
        2. Derby3509_1.diff
          3 kB
          V.Narayanan

          Activity

            People

            • Assignee:
              narayanan V.Narayanan
              Reporter:
              jorgenlo Jorgen Loland
            • Votes:
              0 Vote for this issue
              Watchers:
              0 Start watching this issue

              Dates

              • Created:
                Updated:
                Resolved: