tomaintenance requests may start too early or fail if scheduled in the future

    XMLWordPrintableJSON

Details

    • Bug
    • Status: Resolved
    • Major
    • Resolution: Fixed
    • 2.2.1
    • 2.3
    • vcld (backend)
    • None

    Description

      The utils.pm::checktime subroutine has a bug. It returns "start" 25-30 minutes before a tomaintenance request is supposed to start. It should only return "start" after the start time has been reached. This can cause VMs to be deleted from a host while another reservation is active.

      Also, if a tomaintenance reservation is scheduled in the future, it will likely fail because the computer is not available due to it being automatically reloaded after the reservation is over.