Details
-
Sub-task
-
Status: Closed
-
Minor
-
Resolution: Fixed
-
None
-
None
Description
This is the same projection than Transverse Mercator with only some signs reversed while computing the normalization matrix. The core of the map projection is the same code than SIS-249.
See §1.3.5.3 in IOGP Publication 373-7-2 – Geomatics Guidance Note number 7, part 2 – April 2015.
Attachments
Issue Links
- depends upon
-
SIS-249 Transverse Mercator (EPSG:9807)
- Closed