Description
Some brokers do not supply queuing capabilities. For such brokers, it is necessary to first open a consumer or listener before sending test data. This will allow messages to be buffered locally rather than on the broker.
Change the architecture of the shims such that the receiver is started first, and then later processed for buffered messages.