Exhausting credit on a link can affect other links using the same session.

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: 0.4
    • Fix Version/s: 0.5
    • Component/s: proton-c
    • Labels:
      None

      Description

      Create two sending links on the same connection. On the receiver, grant different credit values to each link. Send enough messages to exhaust credit on each link. Once credit is exhausted on the link with the lesser amount of credit, the remaining link fails to send any more messages.

      See attached test patch.