Details
-
Bug
-
Status: Patch Available
-
Trivial
-
Resolution: Unresolved
-
None
-
None
-
None
Description
In the UI, go in the configuration view of any relationship and provide a flot number for the data size of the back pressure settings like
1.5 GB
When restarting NiFi, warnings will be displayed in the logs:
2020-08-05 17:19:44,092 WARN [main] o.a.nifi.fingerprint.FingerprintFactory Schema validation error parsing Flow Configuration at line 260040, col 58: cvc-pattern-valid: Value '1.5 GB' is not facet-valid with respect to pattern '\d+\s*(B|KB|MB|GB|TB|b|kb|mb|gb|tb)' for type 'DataSize'. 2020-08-05 17:19:44,092 WARN [main] o.a.nifi.fingerprint.FingerprintFactory Schema validation error parsing Flow Configuration at line 260040, col 58: cvc-type.3.1.3: The value '1.5 GB' of element 'maxWorkQueueDataSize' is not valid.
The XSD pattern should be changed to match what is allowed in the UI.
Attachments
Issue Links
- links to