Details
-
Bug
-
Status: Resolved
-
Major
-
Resolution: Fixed
-
None
-
None
-
None
-
Windows (Server 2013 till 10)
Description
Minifi throws this error every 60 seconds
2021-04-07 10:53:05,523 ERROR [Timer-Driven Process Thread-2] o.apache.nifi.controller.FlowController Failed to capture component stats for Stats History java.lang.NullPointerException: null at org.apache.nifi.diagnostics.SystemDiagnostics.getOpenFileHandles(SystemDiagnostics.java:224) at org.apache.nifi.controller.FlowController.getNodeStatusSnapshot(FlowController.java:3056) at org.apache.nifi.controller.FlowController.access$400(FlowController.java:234) at org.apache.nifi.controller.FlowController$2.run(FlowController.java:708) at org.apache.nifi.engine.FlowEngine$2.run(FlowEngine.java:110) at java.util.concurrent.Executors$RunnableAdapter.call(Unknown Source) at java.util.concurrent.FutureTask.runAndReset(Unknown Source) at java.util.concurrent.ScheduledThreadPoolExecutor$ScheduledFutureTask.access$301(Unknown Source) at java.util.concurrent.ScheduledThreadPoolExecutor$ScheduledFutureTask.run(Unknown Source) at java.util.concurrent.ThreadPoolExecutor.runWorker(Unknown Source) at java.util.concurrent.ThreadPoolExecutor$Worker.run(Unknown Source) at java.lang.Thread.run(Unknown Source)
Attachments
Issue Links
- is fixed by
-
NIFI-8400 SystemDiagnostics throws NPE on Windows
-
- Resolved
-