Uploaded image for project: 'Kudu'
  1. Kudu
  2. KUDU-1343

[java client] Scan sequence id is never reset between tablets

    Details

    • Type: Bug
    • Status: Resolved
    • Priority: Blocker
    • Resolution: Fixed
    • Affects Version/s: 0.5.0
    • Fix Version/s: 0.7.1, 0.8.0
    • Component/s: client
    • Labels:
      None

      Description

      AsyncKuduScanner.sequenceId is never reset between tablets, so any multi-batch multi-tablet scan will fail with:

      org.kududb.client.TabletServerErrorException: Server[196dfd5d5e1040dd9963e9b26820078e] INVALID_ARGUMENT[code 4]: Invalid call sequence ID in scan request
      	at org.kududb.client.TabletClient.dispatchTSErrorOrReturnException(TabletClient.java:462)
      

      It's an extremely easy fix, but we need more unit tests.

        Attachments

          Activity

            People

            • Assignee:
              jdcryans Jean-Daniel Cryans
              Reporter:
              jdcryans Jean-Daniel Cryans
            • Votes:
              0 Vote for this issue
              Watchers:
              1 Start watching this issue

              Dates

              • Created:
                Updated:
                Resolved: