Uploaded image for project: 'Apache IoTDB'
  1. Apache IoTDB
  2. IOTDB-1891

【cluster】Got an wrong result with "max_time"

    XMLWordPrintableJSON

Details

    • Bug
    • Status: Closed
    • Major
    • Resolution: Fixed
    • 0.12.2
    • 0.12.4
    • Core/Cluster
    • None

    Description

      Hi IoTDBers:

        I met an bug when I using iotdb-cluster(0.12.2-snapshot).

      1. start iotdb-cluster [3 nodes,default_replica_num=1]
      2. insert data with iotdb-benchmark[read and write]
      3. set ttl=5 days.
      4. select max_time(s_0) from root.test.g_0.d_0
      5. select s_0 from root.test.g_0.d_0 order by time desc limit 10

      Plesae refer to the below picture.

      Now I'm trying to recurrence this bug in v0.12.3 RC1

      Attachments

        Activity

          People

            xiangweiwei Alima777
            QX.Feng FengQingxin
            Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: