    Description

      Scan query map nodes do not take into account topology version when filtering primary partitions. See method GridCacheQueryManager#scanIterator - each node takes it's current topology version. This causes wrong partition filtering results.
      To fix this problem the single topology version should be taken on reduce node propagated to map nodes.