Uploaded image for project: 'Ignite'
  1. Ignite
  2. IGNITE-4799

Remove TcpDiscoverySpi.heartbeatsFrequency parameter

    XMLWordPrintableJSON

Details

    • Bug
    • Status: Resolved
    • Major
    • Resolution: Fixed
    • None
    • 2.0
    • general

    Description

      TcpDiscoverySpi.heartbeatsFrequency is no longer used to adjust the heartbeats frequence. It affects the frequency of metrics messages sent over the cluster ring.

      The following has to be done as a part of 2.0 release:

      • Remove TcpDiscoverySpi.heartbeatsFrequency parameter.
      • Use IgniteConfiguraion.getMetricsUpdateFrequency to adjust the rate of metrics messages.
      • Make sure IgniteConfiguraion.getMetricsUpdateFrequency and metrics messages are not participated in the failure detection process. We have to clean up legacy code in ServerImpl.

      Refer to this discussion for more details:
      http://apache-ignite-developers.2346864.n4.nabble.com/Renaming-TcpDiscoverySpi-heartbeatsFrequency-to-TcpDiscoverySpi-metricsUpdateFrequency-td14941.html

      Attachments

        Issue Links

          Activity

            People

              Unassigned Unassigned
              dmagda Denis A. Magda
              Votes:
              0 Vote for this issue
              Watchers:
              5 Start watching this issue

              Dates

                Created:
                Updated:
                Resolved:

                Time Tracking

                  Estimated:
                  Original Estimate - Not Specified
                  Not Specified
                  Remaining:
                  Remaining Estimate - 0h
                  0h
                  Logged:
                  Time Spent - 16h
                  16h