Description
After updating to calcite 1.33.0 TIMESTAMPDIFF requires some updates as well otherwise we get an error.
Query:
SELECT TIMESTAMPDIFF(SECOND, TIMESTAMP '2022-02-01 10:30:28.123', TIMESTAMP '2022-02-01 10:32:26')
Error:
Caused by: org.apache.ignite.lang.IgniteException: IGN-CMN-65535 TraceId:1d8b4f81-efdf-4208-bff1-e90c607b3981 class org.apache.calcite.sql.SqlIntervalQualifier cannot be cast to class org.apache.calcite.sql.SqlLiteral (org.apache.calcite.sql.SqlIntervalQualifier and org.apache.calcite.sql.SqlLiteral are in unnamed module of loader 'app') at app//org.apache.ignite.lang.IgniteException.wrap(IgniteException.java:289) at app//org.apache.ignite.sql.Session.execute(Session.java:60) at app//org.apache.ignite.internal.sqllogic.ScriptContext.executeQuery(ScriptContext.java:89) at app//org.apache.ignite.internal.sqllogic.Query.execute(Query.java:263) at app//org.apache.ignite.internal.sqllogic.SqlScriptRunner.run(SqlScriptRunner.java:70) ... 6 more Caused by: java.lang.ClassCastException: class org.apache.calcite.sql.SqlIntervalQualifier cannot be cast to class org.apache.calcite.sql.SqlLiteral (org.apache.calcite.sql.SqlIntervalQualifier and org.apache.calcite.sql.SqlLiteral are in unnamed module of loader 'app') at org.apache.ignite.internal.sql.engine.prepare.IgniteConvertletTable$TimestampDiffConvertlet.convertCall(IgniteConvertletTable.java:69)