  3. IGNITE-17875

TX counters with gaps must be logged on every PME

    XMLWordPrintableJSON

Details

    • Sub-task
    • Status: Resolved
    • Major
    • Resolution: Won't Fix
    • None
    • None
    • None

    Description

      TX counters on PME (when all operations are finished) must contain no gaps.
      Such partitions should be listed (with counters) with a special warning.

      Currently, we already have a "Failed to update the counter ..." warning which is logged when the primary tries to set the backup's update counter to its LWM which is less than the backup's HWM.

      But, the better case is to list all broken partitions during the full message calculation during the PME at the coordinator.
      All counters must be listed for every partition which has at least one counter with gaps.