Description
In the Write Pipeline V1 (Async), the topology of the write pipeline is not relevant since the write will always go to the leader regardless.
However, with the support of Streaming Write Pipeline (Write Pipeline V2), the topology of the datanodes in the pipeline needs to be considered to build the optimal pipeline.
This patch will support OM to pass clientMachineString to SCM to get the sorted datanodes.