Description
The changes in PR 2967 introduce a backward incompatible behavior in metric reporting failures where in: Failure in instantiating one of the configured reporters, fails the entire reporting service. Previously, individual reporter failures are swallowed allowing the rest of the reporting service to proceed. The behavior introduced is PR 2967 may be too aggressive and might need a re-think.