Description
If a batch contains duplicate CREATE and DESTROY events on key 1736 like below and conflation is enabled, the earlier events will be overwritten by the later events.
GatewaySenderEventImpl[id=EventID[id=31bytes;threadID=0x30004|6;sequenceID=6072];operation=CREATE;region=/SESSIONS;key=6079], GatewaySenderEventImpl[id=EventID[id=31bytes;threadID=0x30004|6;sequenceID=6073];operation=UPDATE;region=/SESSIONS;key=6079], GatewaySenderEventImpl[id=EventID[id=31bytes;threadID=0x30004|5;sequenceID=6009];operation=CREATE;region=/SESSIONS;key=1736], GatewaySenderEventImpl[id=EventID[id=31bytes;threadID=0x30004|6;sequenceID=6074];operation=DESTROY;region=/SESSIONS;key=6079], GatewaySenderEventImpl[id=EventID[id=31bytes;threadID=0x30004|5;sequenceID=6011];operation=DESTROY;region=/SESSIONS;key=1736], GatewaySenderEventImpl[id=EventID[id=31bytes;threadID=0x30004|6;sequenceID=6087];operation=CREATE;region=/SESSIONS;key=1736], GatewaySenderEventImpl[id=EventID[id=31bytes;threadID=0x30004|6;sequenceID=6089];operation=DESTROY;region=/SESSIONS;key=1736]
The batch will look like this after conflation:
GatewaySenderEventImpl[id=EventID[id=31 bytes;threadID=0x30004|6;sequenceID=6072];operation=CREATE;region=/SESSIONS;key=6079], GatewaySenderEventImpl[id=EventID[id=31 bytes;threadID=0x30004|6;sequenceID=6073];operation=UPDATE;region=/SESSIONS;key=6079], GatewaySenderEventImpl[id=EventID[id=31 bytes;threadID=0x30004|6;sequenceID=6087];operation=CREATE;region=/SESSIONS;key=1736], GatewaySenderEventImpl[id=EventID[id=31 bytes;threadID=0x30004|6;sequenceID=6074];operation=DESTROY;region=/SESSIONS;key=6079], GatewaySenderEventImpl[id=EventID[id=31 bytes;threadID=0x30004|6;sequenceID=6089];operation=DESTROY;region=/SESSIONS;key=1736]
All the events from threadID=0x30004|5 are gone.
Attachments
Issue Links
- links to