Uploaded image for project: 'Flink'
  1. Flink
  2. FLINK-4628

User class loader unavailable during input split assignment

    XMLWordPrintableJSON

Details

    • Bug
    • Status: Closed
    • Minor
    • Resolution: Fixed
    • 1.1.2, 1.2.0
    • 1.2.0
    • Runtime / Coordination
    • None

    Description

      InputFormat\s runs through two configuration phases in the JobManager.

      1. initializeOnMaster which runs the configure() method on the InputFormat
      2. createInputSplits when the ExecutionJobVertex is created

      In 1 we set the user class loader as the context class loader of the executing thread.

      In 2 we only have the system class loader available. If any classes need to be loaded then, we have a problem. Some InputFormats rely on code which lazily load classes at different points in time.

      In particular, this is a problem with the HBase TableInputFormat in the latest master.

      We should make the user class loader available when creating input splits.