18 of the KeyedPartitionWindowedStreamITCase and NonKeyedPartitionWindowedStreamITCase unit tests introduced in FLINK-34543 are failing in the adaptive scheduler profile, with errors similar to:
Mar 15 01:54:12 Caused by: java.lang.IllegalStateException: The adaptive scheduler supports pipelined data exchanges (violated by MapPartition (org.apache.flink.streaming.runtime.tasks.OneInputStreamTask) -> ddb598ad156ed281023ba4eebbe487e3). Mar 15 01:54:12 at org.apache.flink.util.Preconditions.checkState(Preconditions.java:215) Mar 15 01:54:12 at org.apache.flink.runtime.scheduler.adaptive.AdaptiveScheduler.assertPreconditions(AdaptiveScheduler.java:438) Mar 15 01:54:12 at org.apache.flink.runtime.scheduler.adaptive.AdaptiveScheduler.<init>(AdaptiveScheduler.java:356) Mar 15 01:54:12 at org.apache.flink.runtime.scheduler.adaptive.AdaptiveSchedulerFactory.createInstance(AdaptiveSchedulerFactory.java:124) Mar 15 01:54:12 at org.apache.flink.runtime.jobmaster.DefaultSlotPoolServiceSchedulerFactory.createScheduler(DefaultSlotPoolServiceSchedulerFactory.java:121) Mar 15 01:54:12 at org.apache.flink.runtime.jobmaster.JobMaster.createScheduler(JobMaster.java:384) Mar 15 01:54:12 at org.apache.flink.runtime.jobmaster.JobMaster.<init>(JobMaster.java:361) Mar 15 01:54:12 at org.apache.flink.runtime.jobmaster.factories.DefaultJobMasterServiceFactory.internalCreateJobMasterService(DefaultJobMasterServiceFactory.java:128) Mar 15 01:54:12 at org.apache.flink.runtime.jobmaster.factories.DefaultJobMasterServiceFactory.lambda$createJobMasterService$0(DefaultJobMasterServiceFactory.java:100) Mar 15 01:54:12 at org.apache.flink.util.function.FunctionUtils.lambda$uncheckedSupplier$4(FunctionUtils.java:112) Mar 15 01:54:12 at java.util.concurrent.CompletableFuture$AsyncSupply.run(CompletableFuture.java:1604) Mar 15 01:54:12 ... 4 more
Attachments
Issue Links
- links to