The flame graph doesn't work due to groupExecutionsByLocation has bug

    XMLWordPrintableJSON

Details

    Description

      The flame graph cannot be generated forever when multiple tasks in the same TM. It's caused by FLINK-26074

       

      Root cause:

      A Set cannot be converted to an ImmutableSet during the aggregation of ExecutionAttemptIDs. It will cause only the first ExecutionAttemptID of the TM to be added to the set, the second ExecutionAttemptID will fail.

       

       

       

       

       