Details
-
Improvement
-
Status: Resolved
-
Major
-
Resolution: Fixed
-
3.0-incubating
-
None
Description
This may have been done manually one way or another, but I think we should establish a standard process (pref. automated) for Regression Testing.
Suggestion:
- Gather all of the public test clinical notes from the various projects and put it in the ctakes-clinical-pipeline project.
- Write a test case that runs those notes thru the entire default pipeline and compare it with the expected xcas.xml.
- If there is a new module/feature, it should be expected to break the regression test. At that time, it should be manually verified. After the release, the regression test expected results should be re-recorded with the changes.