Uploaded image for project: 'ActiveMQ Classic'
  1. ActiveMQ Classic
  2. AMQ-6687

destination memory usage incorrect after flow control (PFC) sendTimeout and rollback

    XMLWordPrintableJSON

Details

    • Bug
    • Status: Resolved
    • Major
    • Resolution: Fixed
    • 5.14.0
    • 5.15.0
    • Broker
    • None

    Description

      When using PFC, to block a producer on a memory limit and using a sendTimeout to error out after some timeout. If there is a send transaction the send completes in error even though the transaction has completed once usage allows.
      Leaving a dangling send that shows up in the memory usage.

      Attachments

        Issue Links

          Activity

            People

              gtully Gary Tully
              gtully Gary Tully
              Votes:
              0 Vote for this issue
              Watchers:
              2 Start watching this issue

              Dates

                Created:
                Updated:
                Resolved: