      Description

      The "failoverProducersAuditDepth" and "maxFailoverProducersToTrack" settings for MessageDatabase are actually used by the underlying MetaData's ActiveMQMessageAuditNoSync instance. However, the MetaData instance and ActiveMQMessageAuditNoSync may change over the life of the MessageDatabase, and these settings are not perpetuated to the new instances (or restored instances).