When creating a new HTTP connector the values provided for minSpareThreads, maxSpareThreads and maxThreads attributes are lost in the server.xml file after commiting changes. Steps to reproduce: 1/ Create a HTTP connector with the Tomcat Administration Tool. Feel in values for the minSpareThreads, maxSpareThreads and maxThreads attributes. 2/ Click on Save button 3/ Click on Commit Changes button 4/ Check newly created <connector> item in server.xml file: missing above configuration attributes
Correcting component. Please try in 5.5.9 when it comes out in a few days.
Well, if you try it out in 5.5.10 and it doesn't work, please let us know.