Uploaded image for project: 'Traffic Server'
  1. Traffic Server
  2. TS-3947

Intermittent HTTP/2 failure with h2spec (6.9.1.)

    XMLWordPrintableJSON

Details

    • Bug
    • Status: Open
    • Major
    • Resolution: Unresolved
    • None
    • 7.1.0
    • HTTP/2
    • None

    Description

      I see this once in a while (not frequently)

          6.9.1. The Flow Control Window
            ✓ Sends multiple WINDOW_UPDATE frames on a connection increasing the flow control window to above 2^31-1
            × Sends multiple WINDOW_UPDATE frames on a stream increasing the flow control window to above 2^31-1
              - The endpoint MUST sends a RST_STREAM with the error code of FLOW_CONTROL_ERROR code.
                Expected: RST_STREAM frame (ErrorCode: FLOW_CONTROL_ERROR)
                  Actual: DATA frame (Length: 257, Flags: 1)
      

      Attachments

        Issue Links

          Activity

            People

              masaori Masaori Koshiba
              zwoop Leif Hedstrom
              Votes:
              0 Vote for this issue
              Watchers:
              2 Start watching this issue

              Dates

                Created:
                Updated: