Uploaded image for project: 'Traffic Server'
  1. Traffic Server
  2. TS-3947

Intermittent HTTP/2 failure with h2spec (6.9.1.)

    XMLWordPrintableJSON

    Details

    • Type: Bug
    • Status: Open
    • Priority: Major
    • Resolution: Unresolved
    • Affects Version/s: None
    • Fix Version/s: 7.1.0
    • Component/s: HTTP/2
    • Labels:
      None

      Description

      I see this once in a while (not frequently)

          6.9.1. The Flow Control Window
            ✓ Sends multiple WINDOW_UPDATE frames on a connection increasing the flow control window to above 2^31-1
            × Sends multiple WINDOW_UPDATE frames on a stream increasing the flow control window to above 2^31-1
              - The endpoint MUST sends a RST_STREAM with the error code of FLOW_CONTROL_ERROR code.
                Expected: RST_STREAM frame (ErrorCode: FLOW_CONTROL_ERROR)
                  Actual: DATA frame (Length: 257, Flags: 1)
      

        Attachments

          Issue Links

            Activity

              People

              • Assignee:
                masaori Masaori Koshiba
                Reporter:
                zwoop Leif Hedstrom
              • Votes:
                0 Vote for this issue
                Watchers:
                2 Start watching this issue

                Dates

                • Created:
                  Updated: