Uploaded image for project: 'Stratos'
  1. Stratos
  2. STRATOS-1484

Spin a new member after the termination of existing member

    Details

    • Type: Improvement
    • Status: Resolved
    • Priority: Major
    • Resolution: Done
    • Affects Version/s: 4.1.0
    • Fix Version/s: 4.1.1
    • Component/s: Autoscaler
    • Labels:
      None

      Description

      In order to optimize the performance, stratos 4.1.0 supported member spinning in parallel to the member termination. But when having member min and max as 1 and when this particular member uses limited resources, it will not be possible to create a member in order to replace the existing one in the case of member faulty occurred. To avoid such situation, stratos has to wait for the proper termination of existing member before creating a new one.

      This can be configured in autoscaler.xml as below:

      <spinAfterTerminate>true</spinAfterTerminate>