Uploaded image for project: 'Qpid'
  1. Qpid
  2. QPID-4017

AMQP 0-9: Failover causes flow control blocked flag to get stuck

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: 0.10, 0.12, 0.14, 0.16
    • Fix Version/s: 0.17
    • Component/s: JMS AMQP 0-x
    • Labels:
      None

      Description

      When testing failover with a single broker, we observed problems if a session is currently blocked due to flow control. Following the broker restart, the session is reestablished but it remains blocked forever.

      The fix is to reset the blocked flag during failover.