Uploaded image for project: 'Qpid'
  1. Qpid
  2. QPID-4017

AMQP 0-9: Failover causes flow control blocked flag to get stuck

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: 0.10, 0.12, 0.14, 0.16
    • Fix Version/s: 0.17
    • Component/s: Java Client
    • Labels:
      None

      Description

      When testing failover with a single broker, we observed problems if a session is currently blocked due to flow control. Following the broker restart, the session is reestablished but it remains blocked forever.

      The fix is to reset the blocked flag during failover.

        Activity

        Hide
        gemmellr Robbie Gemmell added a comment -

        Patch applied, along with some updates from joint review with Phil.

        Show
        gemmellr Robbie Gemmell added a comment - Patch applied, along with some updates from joint review with Phil.

          People

          • Assignee:
            philharveyonline Philip Harvey
            Reporter:
            alex.rufous Alex Rudyy
          • Votes:
            0 Vote for this issue
            Watchers:
            2 Start watching this issue

            Dates

            • Created:
              Updated:
              Resolved:

              Development