Uploaded image for project: 'Apache NiFi'
  1. Apache NiFi
  2. NIFI-5030

ControlRate stops allowing FlowFiles through from same connection once limit for any 'group' is reached

    XMLWordPrintableJSON

Details

    • Bug
    • Status: Resolved
    • Major
    • Resolution: Fixed
    • None
    • 1.6.0
    • Extensions
    • None

    Description

      If we have FlowFiles in a single connection that feed into ControlRate, and we use the "Grouping Attribute" property, then whenever the processor encounters one FlowFile that should not continue on, subsequent FlowFiles in the queue will also not be transferred on either, even if they are of a different group.

      Attachments

        Issue Links

          Activity

            People

              markap14 Mark Payne
              markap14 Mark Payne
              Votes:
              0 Vote for this issue
              Watchers:
              4 Start watching this issue

              Dates

                Created:
                Updated:
                Resolved: