Uploaded image for project: 'Apache NiFi'
  1. Apache NiFi
  2. NIFI-4263

Schema validation error parsing Flow Configuration, Back Pressure Data Size Threshold value

    XMLWordPrintableJSON

Details

    • Improvement
    • Status: Open
    • Minor
    • Resolution: Unresolved
    • None
    • None
    • None

    Description

      In a connection, if the Back Pressure Data Size Threshold has a space at the end of the value, NiFi will throw the following warning.
      WARN [main] o.a.n.c.StandardFlowSynchronizer Schema validation error parsing Flow Configuration at line 4774, col 58: cvc-type.3.1.3: The value '50 mb ' of element 'maxWorkQueueDataSize' is not valid.

      The validator regex should be updated to handle this possibility and not throw the warning.