Uploaded image for project: 'Ignite'
  1. Ignite
  2. IGNITE-7506

GridClusterStateProcessor#compatibilityMode flag never gets reset to false

    XMLWordPrintableJSON

Details

    • Bug
    • Status: Resolved
    • Major
    • Resolution: Fixed
    • 2.4
    • 2.4
    • persistence
    • None

    Description

      When Ignite node of version 2.4+ joins cluster with older versions of Ignite running it sets compatibilityMode flag to handle **cluster state in a special way (excluding BaselineTopology from discovery exchange process and so on).

      But when all old nodes are turned off there is no way except full cluster restart to enable setting very first **BaselineTopology.

      This should be addressed and some way to exit compatibilityMode without full cluster restart should be provided.

      Attachments

        Issue Links

          Activity

            People

              sergey-chugunov Sergey Chugunov
              sergey-chugunov Sergey Chugunov
              Votes:
              0 Vote for this issue
              Watchers:
              2 Start watching this issue

              Dates

                Created:
                Updated:
                Resolved: