Uploaded image for project: 'Ignite'
  1. Ignite
  2. IGNITE-6590

TCP port in bin/control.sh differs from default

    XMLWordPrintableJSON

    Details

    • Type: Bug
    • Status: Resolved
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: 2.2
    • Fix Version/s: 2.4
    • Component/s: clients, control.sh
    • Labels:
      None

      Description

      % bin/ignite.sh -v
      >>> Local ports: TCP:8081 TCP:10800 TCP:11211 TCP:47100 TCP:47500 
      
      % bin/control.sh --host 127.0.0.1
      окт 10, 2017 3:01:26 PM org.apache.ignite.internal.client.impl.GridClientImpl <init>
      WARNING: Failed to initialize topology on client start. Will retry in background.
      Caused by: class org.apache.ignite.internal.client.GridServerUnreachableException: Failed to connect to any of the servers in list: [/127.0.0.1:11212]
      

      11212 != 11211. But it's very hard to spot visually. Please fix control.sh to use correct port by default.

        Attachments

          Activity

            People

            • Assignee:
              MikeZhur Mike Zhuravlev
              Reporter:
              ilyak Ilya Kasnacheev
            • Votes:
              0 Vote for this issue
              Watchers:
              3 Start watching this issue

              Dates

              • Created:
                Updated:
                Resolved:

                Time Tracking

                Estimated:
                Original Estimate - Not Specified
                Not Specified
                Remaining:
                Remaining Estimate - 0h
                0h
                Logged:
                Time Spent - 20m
                20m