    Description

      % bin/ignite.sh -v
      >>> Local ports: TCP:8081 TCP:10800 TCP:11211 TCP:47100 TCP:47500 
      
      % bin/control.sh --host 127.0.0.1
      окт 10, 2017 3:01:26 PM org.apache.ignite.internal.client.impl.GridClientImpl <init>
      WARNING: Failed to initialize topology on client start. Will retry in background.
      Caused by: class org.apache.ignite.internal.client.GridServerUnreachableException: Failed to connect to any of the servers in list: [/127.0.0.1:11212]
      

      11212 != 11211. But it's very hard to spot visually. Please fix control.sh to use correct port by default.