Description
- Ignite.memoryMetrics() returns a collection of metrics. However, it’s unclear what exactly the collection includes. Is every element of the collection is a latest snapshot of a specific memory region defined by memory policy and the the total size of the collection is equal to the total number of such regions configured on a node? This has to be clarified in java doc before 2.0 release.
- I would have Ignite.memoryMetrics(name) methods that will return the metrics for a concrete region configured by memory policy. It’s fine to add the method under 2.1 (create a ticket).
- I would add “setRateInterval” and “setSubIntervals” methods to MemoryPolicyConfiguration because now I have to get a JMX bean if to want to change the parameter. Again, feel free do this under 2.0 or move to 2.1 if there is no time for that.
Original discussion: http://apache-ignite-developers.2346864.n4.nabble.com/MemoryMetrics-interface-inconsistencies-td17156.html
Attachments
Issue Links
- is related to
-
IGNITE-5273 .NET: MemoryMetrics API improvements to be ported to .NET
- Resolved