    Description

      When executing an RO transaction, readTimestamp has to be determined. If MaxObservableTimestamp is not available (which is currently true after a DDL), then TxManagerImpl takes readTimestamp as HLC.now() - idleSafeTimePropagationPeriod - MaxClockSkew.

      In IGNITE-20668, an additional wait after a DDL operation was added to make sure that a readTimestamp calculated in this way does not look before the DDL (otherwise, the RO would see the previous schema). But in IGNITE-20668, only idleSafeTimePropagationPeriod was added after a DDL, and MaxClockSkew component was forgotten.

      We must add MaxClockSkew to the wait.