Description
Need to provide stronger data loss check.
Currently node can fire event - EVT_CACHE_REBALANCE_PART_DATA_LOST
However, this is not enough since if there is strong requirement on application behavior on data loss e.g. further cache updates should throw exception - this requirement cannot currently be met even with use of cache interceptor.
Suggestions:
- Introduce CacheDataLossPolicy enum: FAIL_OPS, NOOP and put it to configuration
- If node fires PART_LOST_EVT then any update to lost partition will throw (or will not throw) exception according to DataLossPolicy
- ForceKeysRequest should be completed with exception (if plc == FAIL) if all nodes to request from are gone. So, all gets/puts/txs should fail.
- Add a public API method in order to allow a recovery from a failed state.
Another solution is to detect partition loss at the time partition exchange completes. Since we hold topology lock during the exchange, we can easily check that there are no owners for a partition and act as a topology validator in case FAIL policy is configured. There is one thing needed to be carefully analyzed: demand worker should not park partition as owning in case last owner leaves grid before the corresponding exchange completes.
Attachments
Issue Links
- is duplicated by
-
IGNITE-13003 Improve data loss handling
- Resolved
- is related to
-
IGNITE-2378 Data loss Part 2. Add flexible DataLoss Policy. Improve dataLoss event with batch.
- Open
- links to
- mentioned in
-