Details
-
Bug
-
Status: Resolved
-
Major
-
Resolution: Fixed
-
2.7
-
None
Description
If a server node killed with the disabled wal archive, it could fail on start with following exception:
[18:37:53,887][SEVERE][sys-stripe-1-#2][G] Failed to execute runnable. java.lang.IllegalStateException: Failed to get page IO instance (page content is corrupted) at org.apache.ignite.internal.processors.cache.persistence.tree.io.IOVersions.forVersion(IOVersions.java:85) at org.apache.ignite.internal.processors.cache.persistence.tree.io.IOVersions.forPage(IOVersions.java:97) at org.apache.ignite.internal.pagemem.wal.record.delta.MetaPageUpdatePartitionDataRecord.applyDelta(MetaPageUpdatePartitionDataRecord.java:109) at org.apache.ignite.internal.processors.cache.persistence.GridCacheDatabaseSharedManager.applyPageDelta(GridCacheDatabaseSharedManager.java:2532) at org.apache.ignite.internal.processors.cache.persistence.GridCacheDatabaseSharedManager.lambda$performBinaryMemoryRestore$11(GridCacheDatabaseSharedManager.java:2327) at org.apache.ignite.internal.processors.cache.persistence.GridCacheDatabaseSharedManager.lambda$stripedApplyPage$12(GridCacheDatabaseSharedManager.java:2441) at org.apache.ignite.internal.processors.cache.persistence.GridCacheDatabaseSharedManager.lambda$stripedApply$13(GridCacheDatabaseSharedManager.java:2479) at org.apache.ignite.internal.util.StripedExecutor$Stripe.body(StripedExecutor.java:550) at org.apache.ignite.internal.util.worker.GridWorker.run(GridWorker.java:120) at java.lang.Thread.run(Thread.java:748)
The reproducer is attached(works only on Linux).
Steps to run the reproducer.
1. Copy config/server.xml into IGNITE_HOME/config folder;
2. Set IGNITE_HOME in the CorruptionReproducer class;
3. Launch CorruptionReproducer.
Attachments
Attachments
Issue Links
- links to