HBase
  1. HBase
  2. HBASE-6535

[replication] replication will be block if WAL compress set differently in master and slave cluster configuration

    Details

    • Type: Bug Bug
    • Status: Resolved
    • Priority: Major Major
    • Resolution: Duplicate
    • Affects Version/s: 0.94.0
    • Fix Version/s: None
    • Component/s: Replication
    • Labels:
      None

      Description

      As we know in hbase 0.94.0 we have a configuration below
      <property>
      <name>hbase.regionserver.wal.enablecompression</name>
      <value>true</value>
      </property>
      if we enable it in master cluster and disable it in slave cluster . Then replication will not work. It will throw unwrapRemoteException again and again in master cluster because slave can not parse the hlog entry buffer.

        Issue Links

          Activity

            People

            • Assignee:
              Unassigned
              Reporter:
              terry zhang
            • Votes:
              0 Vote for this issue
              Watchers:
              0 Start watching this issue

              Dates

              • Created:
                Updated:
                Resolved:

                Development