      Description

      As we know in hbase 0.94.0 we have a configuration below
      <property>
      <name>hbase.regionserver.wal.enablecompression</name>
      <value>true</value>
      </property>
      if we enable it in master cluster and disable it in slave cluster . Then replication will not work. It will throw unwrapRemoteException again and again in master cluster because slave can not parse the hlog entry buffer.

        Issue Links

          Activity

          terry zhang created issue -
          Michael Drzal made changes -
          Field Original Value New Value
          Link This issue duplicates HBASE-6533 [ HBASE-6533 ]
          Michael Drzal made changes -
          Status Open [ 1 ] Resolved [ 5 ]
          Resolution Duplicate [ 3 ]