      Description

      In ReduceTask.java, The parameters for method calls for getInputStream(URLConnection connection, int connectionTimeout, int readTimeout) should be in that order. Now it is

              InputStream input = getInputStream(connection, DEFAULT_READ_TIMEOUT, 
                                                 STALLED_COPY_TIMEOUT);
      

      It works now because both DEFAULT_READ_TIMEOUT and STALLED_COPY_TIMEOUT have the same value.