INFO org.apache.hadoop.ipc.Server: IPC Server listener on 8020: readAndProcess from client 10.115.201.46 threw exception org.apache.hadoop.ipc.RpcServerException: Unknown out of band call #-2147483647
This is thrown by a reader thread, so the message should be like
INFO org.apache.hadoop.ipc.Server: Socket Reader #1 for port 8020: readAndProcess from client 10.115.201.46 threw exception org.apache.hadoop.ipc.RpcServerException: Unknown out of band call #-2147483647