Uploaded image for project: 'Flink'
  1. Flink
  2. FLINK-22200

Flink SQL Client Error with: Could not find any factory for identifier 'hudi' that implements 'org.apache.flink.table.factories.DynamicTableSourceFactory

    XMLWordPrintableJSON

Details

    • Bug
    • Status: Closed
    • Blocker
    • Resolution: Won't Fix
    • 1.11.3
    • None
    • Table SQL / Ecosystem
    • None

    Description

      When use hudi-flink with Flink SQL to perform stream read. The Flink SQL client failed to submit job with the following error:

      Flink version: 1.11.3

      Hadoop version 2.10.1

      hudi-flink: hudi-flink-bundle_2.11-0.8.0.jar

      Flink SQL> create table t1(
      > uuid varchar(20),
      > name varchar(10),
      > age int,
      > ts timestamp(3),
      > `partition` varchar(20)
      > )
      > PARTITIONED BY (`partition`)
      > with (
      > 'connector' = 'hudi',
      > 'path' = 'file:///hudi/t1',
      > 'table.type' = 'MERGE_ON_READ',
      > 'read.streaming.enabled' = 'true',
      > 'read.streaming.check-interval' = '4'
      > );
      [INFO] Table has been created.

      Flink SQL> set execution.result-mode=tableau;
      [INFO] Session property has been set.

      Flink SQL> select * from t1;
      [ERROR] Could not execute SQL statement. Reason:
      org.apache.flink.table.api.ValidationException: Could not find any factory for identifier 'hudi' that implements 'org.apache.flink.table.factories.DynamicTableSourceFactory' in the classpath.

      Available factory identifiers are:

      datagen

      Flink SQL>

       

      Attachments

        Activity

          People

            Unassigned Unassigned
            pchen@nd.com Phil Chen
            Votes:
            0 Vote for this issue
            Watchers:
            4 Start watching this issue

            Dates

              Created:
              Updated: