Details
-
Bug
-
Status: Closed
-
Major
-
Resolution: Fixed
-
0.8.0
-
None
-
None
Description
In some circumstances, e.g. under CI with limited CPU, an auto-link that is configured to be setup when a matching container connects in to the router will fail to trigger. This is because the qdr_connection_t and the qd_connection_t are not linked together in time at the point the connection is activated by the core thread (responding to the qdr_connection_opened event), so the connection never gets a wakeup event and never checks for actions.