Uploaded image for project: 'Derby'
  1. Derby
  2. DERBY-3705

In Net Client mode, negative values for stream length are accepted without an exception for PreparedStatement.setAsciiStream()

Attach filesAttach ScreenshotVotersWatch issueWatchersCreate sub-taskLinkCloneUpdate Comment AuthorReplace String in CommentUpdate Comment VisibilityDelete Comments
    XMLWordPrintableJSON

    Details

    • Type: Bug
    • Status: Closed
    • Priority: Minor
    • Resolution: Fixed
    • Affects Version/s: 10.4.1.3, 10.5.1.1
    • Fix Version/s: 10.5.1.1
    • Component/s: Network Client
    • Labels:
      None
    • Environment:
      Windows XP SP2, Derby trunk SVN checkout
    • Urgency:
      Normal

      Description

      This is related to Cloudscape bug 4250.

      Pass negative length as the stream length for various setXXXStream methods should throw an exception. But in Net Client mode, passing a negative value as stream length to PreparedStatement.setAsciiStream() doesn't throw an exception.

      e.g. //from store/StreamingColumn
      PreparedStatement ps = prepareStatement("insert into "
      + "testLongVarCharInvalidStreamLength11 values(?, ?, ?)");
      ps.setInt(1, 100);
      try

      { println("===> testing using setAsciiStream with -2 as length"); ps.setAsciiStream(2, fileIn, -2); // should throw exception here but doesn't. }

      This issue has been fixed for embedded mode, but not for client mode.

        Attachments

        1. derby-3705.diff
          2 kB
          Suran Jayathilaka
        2. derby-3705-2.diff
          4 kB
          Suran Jayathilaka
        3. derby-3705-2b.diff
          4 kB
          Kristian Waagan

        Issue Links

          Activity

            People

            • Assignee:
              suranjay Suran Jayathilaka
              Reporter:
              suranjay Suran Jayathilaka

              Dates

              • Created:
                Updated:
                Resolved:

                Issue deployment