Details
-
Improvement
-
Status: Resolved
-
Major
-
Resolution: Fixed
-
OpenCMIS 0.9.0
-
None
-
None
Description
When using the Workbench, there is something fishy going on with the major version checkbox. It doesn't always give you the major/minor version you ask for by checking/unchecking the major/minor box. It appears to give you what you ask for on the second check in. It then works correctly on subsequent checkins until you change the checkbox. It will then begin working correctly again on the second attempt and so on.
For example:
Create object -> V 1.0
Checkout object
Check-in. Do not change major/minor flag (it should be checked) -> V 2.0
Checkout object
Check-in. Uncheck box. -> V 3.0 (expected V 2.1)
Checkout object
Check-in. Do not change major/minor flag (it should be UNchecked) -> V 3.1
Checkout object
Check-in. Check box. -> V 3.2 (expected V 4.0)
Checkout object
Check-in. Do not change major/minor flag (it should be checked) -> V 4.0