Uploaded image for project: 'Aurora'
  1. Aurora
  2. AURORA-1260

job restart reports successful restart when it fails

    XMLWordPrintableJSON

Details

    • Bug
    • Status: Resolved
    • Major
    • Resolution: Duplicate
    • None
    • 0.8.0
    • Client

    Description

      $ aurora job restart devcluster/davmclau/devel/hello_world
       INFO] Performing rolling restart of job devcluster/davmclau/devel/hello_world (instances: [0, 1, 2])
       INFO] Restarting instances: [0]
       INFO] Watching instances: [0]
       INFO] Instance 0 was not reported healthy within 60 seconds
      ERROR] 1 failed instances observed, maximum allowed is 0
      ERROR] 1 instance failures for instance 0, maximum allowed is 0
      ERROR] 1 failed instances observed, maximum allowed is 0
      ERROR] 1 instance failures for instance 0, maximum allowed is 0
       INFO] Restart failures threshold reached. Aborting
      Job devcluster/davmclau/devel/hello_world restarted successfully
      

      Attachments

        Issue Links

          Activity

            People

              Unassigned Unassigned
              davmclau David McLaughlin
              Votes:
              0 Vote for this issue
              Watchers:
              1 Start watching this issue

              Dates

                Created:
                Updated:
                Resolved: