      I think (based on what ActiveMQ has as its defaults) that the max_inactivity_duration and max_inactivity_duration_initial_delay default values might be incorrect. ActiveMQ has them at 30s:
      From: OpenWireFormatFactory:
      private long maxInactivityDuration = 30*1000;
      private long maxInactivityDurationInitalDelay = 10*1000;

      But Apollo has them set for 8.33 hrs:
      DEFAULT_WIREFORMAT_SETTINGS.setMaxInactivityDuration(30 * 1000 * 1000);
      DEFAULT_WIREFORMAT_SETTINGS.setMaxInactivityDurationInitalDelay(10 * 1000 * 1000);

      Patch is easy, can submit it, but just wanted to confirm that this is indeed wrong?