Uploaded image for project: 'ActiveMQ .Net'
  1. ActiveMQ .Net
  2. AMQNET-511

Failover mode is not enabled for TIBCO provider

    XMLWordPrintableJSON

    Details

    • Type: Bug
    • Status: Resolved
    • Priority: Major
    • Resolution: Fixed
    • Affects Version/s: 1.5.0, 1.7.0
    • Fix Version/s: 1.7.1, 1.8.0
    • Component/s: EMS
    • Labels:

      Description

      When attempting to use a failover URI, the TIBCO provider does not actually activate the failover mode.

      Given a simple failover URI: ems:tcp://emsbroker1:7222,tcp://emsbroker2:7222

      This should enable failover and auto-reconnect in case of network disruption. However, it only throws an exception and never attempts to reconnect.

        Attachments

          Activity

            People

            • Assignee:
              jgomes Jim Gomes
              Reporter:
              jgomes Jim Gomes
            • Votes:
              0 Vote for this issue
              Watchers:
              2 Start watching this issue

              Dates

              • Created:
                Updated:
                Resolved:

                Time Tracking

                Estimated:
                Original Estimate - 4h
                4h
                Remaining:
                Remaining Estimate - 4h
                4h
                Logged:
                Time Spent - Not Specified
                Not Specified