Uploaded image for project: 'ActiveMQ Classic'
  1. ActiveMQ Classic
  2. AMQ-4399

jdbcPersistenceAdapter takes a long time to shutdown, causing journal recovery

    XMLWordPrintableJSON

Details

    • Improvement
    • Status: Resolved
    • Major
    • Resolution: Fixed
    • 5.7.0
    • 5.10.0
    • Broker
    • None
    • 5.7.0.fuse-71-047
      MySQL with Journal

    Description

      Using the attached configuration, we have configured JDBC persistence with a journal. After sending 30,000 messages to a queue, using persistent messages, we see that shutdown of the broker timeouts out and the process is killed by the OS.

      After restarting the broker, a journal recovery takes place, which takes a long time to complete. We would like to avoid such a long restart time in this scenario.

      Attachments

        1. activemq.xml
          3 kB
          Jason Shepherd

        Activity

          People

            davsclaus Claus Ibsen
            jshepher Jason Shepherd
            Votes:
            0 Vote for this issue
            Watchers:
            3 Start watching this issue

            Dates

              Created:
              Updated:
              Resolved: